• CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
  • CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
  • CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
  • CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
  • CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
  • CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard

CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard

After-sales Service: 24 Hours Technical Support
Warranty: 3 Years
Type: Parameter Verification Testing Machine
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard pictures & photos
CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
US $8,250-9,200 / Set
Min. Order: 1 Set
Gold Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
  • Main Features
  • Technical Principle
  • Product Parameters
  • Detailed Photos
  • Applications
  • Company Profile
Overview

Basic Info.

Model NO.
CTP200P
Accuracy Grade
0.05%
Display
Digital
Control
Computer & Manual Control
Weight
19kg
Power Source
AC100V-240V 50/60Hz
Current Transformer Test
Available
Voltage Transformer Test
Available
Maximum Knee Point
40kv Higher
CT Classes
Tp,Inductive,Protective,Measuring
Testing Method
Low-Frequency
Ratio Test
Available
Polarity
Available
Ratio Error
Available
Phase Error
Available
Power Supply
110V/220V 50Hz/60Hz
IEC Standard
IEC61869-2(IEC60044-1,60044-6)
IEC Standard1
IEC61869-3(IEC60044-2)
IEEE/ANSI
C57.13
Transport Package
Explosion Proof Box
Specification
340*300*150mm
Trademark
CTP
Origin
Wuhan
HS Code
9030820000
Production Capacity
300set/Week

Packaging & Delivery

Package Size
59.00cm * 41.00cm * 77.00cm
Package Gross Weight
29.000kg

Product Description

Product Description

CT analyzer according to IEC61869-2/3 and IEEE/ANSI C57.13 standard

Model No.: CTP-200P

Descriptions:
CT and PT Analyzer is the revolutionary testing system for various CTs and PTs according to standards IEC61869-2 (IEC60044-1,60044-6), IEC61869-3(IEC60044-2) and IEEE/ANSI C57.13.The Analyzer can automatically complete the test within seconds by one click of the patented multifunctional rotary mouse.It allows to test the knee-point voltage up to 40kV CTs and PTs on-site in power grids or in manufacturers' production facilities or test labs. 

CT and PT Tester CTP-200 is only 9kg(9.84 lbs), which is easy to carry on testing site.
Main Free Application
-CT/PT excitation and saturation test
-Accuracy measurement of ratio and phase angle
-Secondary loop burden measurement
-Winding resistance measurement
-Saturated and non-saturated inductance test
-Transient CT parameters test
-CT/PT polarity test
-CT nameplate guess

CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
 

Main Features

1) Able to test Protection CTs, Measuring CTs, TP class CTs and inductive PTs
2) Test excitation characteristic and error curve based on low-frequency measurement principle
3) Measure ratio, polarity, ratio error and phase displacement error based on voltage method
4) Automatic demagnetization of the CT after test.
5) Adopt patented multifunctional rotary mouse to replace the keypad
6) Adopt 5.7 inches LCD screen for display
7) Adopt DSP, ARM and embedded LINUX operation system
8) Both local test and PC remote test available
9) Higher measurement accuracy: 0.05 %
10) Print test results directly by built-in thermal printer
11) Small and light weight (9kg / 19.84 lbs) for easy transport
 

Technical Principle

 

Ratio error and phase angle error of CT tested by voltage measurement method 
CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard

Figure1 CT's equivalence principle diagram

CT's equivalence principle is shown as figure1.
The main reason of causing ratio error and phase angle error is the error of excitation loss's current Iex and turns ratio Np/Ns. So for 5%, 20%,100%,120% rated current output, if Iex amplitude and phase position and true turns ratio Np/Ns are known, then the ratio error and angle error of CT at this time can be calculated. The tester calculates the ratio error and phase angle error of CT by the measured turns ratio Np/Ns and excitation loss Iex.

 

Turns Ratio Np/Ns can be got by inputting voltage on the secondary side under no-load condition and test the primary induced voltage. Iex can be got by test the secondary side's excitation characteristics. Because Iex is determined by the induced electromotive force of secondary circuit, Iex amplitude and phase angle can be got from excitation characteristics. When the secondary current and the secondary load are known, Vex value is also can be got by calculation and get Iex value by checking out the excitation characteristics data table.
CT and PT Tester CTP-200P was showed at THE 9TH INTERNATIONAL EXHIBITION ON ELECTRICAL TECHNOLOGY & EQUIPMENT in SECC, Ho Chi Minh City. 

Product Parameters

Test Standard IEC61869-2(IEC60044-1,60044-6), IEC61869-3(IEC60044-2), IEEE/ANSI C57.13
Maximum Knee Voltage Measurement 40kV
Output Range - Voltage 0~180V(RMS)
Output Range - Current 0~12A(RMS), 36A(peak value)
Voltage Measurement Accuracy ±0.05%
CT Ratio Measurement - Range 1~40000
CT Ratio Measurement - Accuracy ±0.05%
PT Ratio Measurement - Range 1~10000
PT Ratio Measurement - Accuracy ±0.05%
Phase Measurement - Accuracy ±2min
Phase Measurement - Resolution 0.01min
Secondary Winding Resistance - Range 0~300Ω
Secondary Winding Resistance - Accuracy 0.1%±1mΩ
Burden Measurement - Range 0~300VA
Burden Measurement - Accuracy 0.1%±0.1VA
Memory Capacity >3000 groups test results

○Power Supply

Nominal Input Voltage

Customized (AC 220V/230V/120V/127V±10%, 1-Phase)

Nominal Frequency

50/60 Hz

Rated Current

10A At 230V / 12A At 115V

Connection

Standard AC Socket (IEC 60320)

 

○Environmental Conditions

Operation Temperature

0 ... +50 °C (+32 ... +122 °F)

Storage Temperature

-25 ... +70 °C (-13 ... +158 °F)

Humidity Range

Relative Humidity 5 ... 95 %, Non-Condensing

Vibration

IEC 60068-2-6(20m/S2 At 10 ... 150 Hz)

 

○Miscellaneous

Weight

9kg / 19.84 Lbs

Dimensions (W X H X D, Without Handle)

340×300×150mm(13.39x11.81x5.91 In)

Connection Port

2 USB2.0 Ports, 1 Communication Port

 

○Safety Standards, Electromagnetic Compatibility

EMC

The Product Adheres To The Electromagnetic Compatibility (EMC) Directive 2004/108/EC(CE Conform)

IEC 61326-1; IEC 61000-6-4; IEC 61000-3-2/3

Safety

The Product Adheres To The Low Voltage Directive 2006/95/EC(CE Conform).

IEC 61010-1

 

Detailed Photos

CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard

CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
 
CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
 

Applications

 

CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 StandardCT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard

Company Profile

HAOMAI ELECTRIC POWER AUTOMATION is established in 1999 and located in Wuhan of China, which is specialized in developing and manufacturing electrical power test and measurement instruments. HAOMAI products are widely used in power grid, petrochemical, metallurgy, railway, coal mine, research institutes and all kinds of large-scale factories or enterprises.mainly focuses on the sales and services of Protection Relay Test System, CT/PT Analyzer, Battery Load Tester, Transformer Testing Equipment, Circuit Breaker Analyzer, Partial Discharge Detector etc. electrical power test and measurement instruments.
 
CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard


HAOMAI is China well-known mark recognized and approved by State Administration for Industry & Commerce of People's Republic of China, and enjoys high reputation in domestic and foreign markets.HAOMAI now is the key supplier for SGCC(State Grid Corporation of China) and CSG(China Southern Power Grid). Till 2018 HAOMAI products have been sold to 34 different countries.  
HAOMAI always sticks to the faith of "cooperation and sharing", takes the "technology and market" as the direction, "creation and innovation" as the soul, listens to clients carefully, and improves the technology, upgrades the products, optimizes the service and tries all to be the global leader in electrical power test and measurement instruments field.

CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard pictures & photos
CT Analyzer According to IEC61869-2/3 and IEEE/ANSI C57.13 Standard
US $8,250-9,200 / Set
Min. Order: 1 Set
Gold Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Number of Employees
249
Year of Establishment
1999-07-27