Basic Info.
Max Diameter of Workpiece
<500mm
Mass Scope of Workpiece
<900kg
Type
Electric Power Tester
Maxcapacity
Electric Power Tester
Loading Method
Dynamic Load
Connection Port
2 USB2.0 Ports, 1 Communication Port
Testing Method
Secondary Injects Low Test Signals
Calibration Acuracy
0.05%
Knee Voltage Measuring Range
>30kv
Transport Package
Standard Export Wooden Package
Specification
340× 300× 150mm
Product Description
Product Description
Descriptions
CT and PT Tester is the revolutionary testing system for various CTs and PTs according to standards IEC61869-2 (IEC60044-1,60044-6), IEC61869-3(IEC60044-2) and IEEE/ANSI C57.13. The Analyzer can automatically complete the test within seconds by one click of the patented multifunctional rotary mouse. It allows to test the knee-point voltage up to 40kV CTs and PTs on-site in power grids or in manufacturers' production facilities or test labs.
CT and PT Tester CTP-200 is only 9kg(9.84 lbs), which is easy to carry on testing site.
Main Features
1) Able to test Protection CTs, Measuring CTs, TP class CTs and inductive PTs
2) Test excitation characteristic and error curve based on low-frequency measurement principle
3) Measure ratio, polarity, ratio error and phase displacement error based on voltage method
4) Automatic demagnetization of the CT after test.
5) Adopt patented multifunctional rotary mouse to replace the keypad
6) Adopt 5.7 inches LCD screen for display
7) Adopt DSP, ARM and embedded LINUX operation system
8) Both local test and PC remote test available
9) Higher measurement accuracy: 0.05 %
10) Print test results directly by built-in thermal printer
11) Small and light weight (9kg / 19.84 lbs) for easy transport
Application
-CT/PT excitation and saturation test
-Accuracy measurement of ratio and phase angle
-Secondary loop burden measurement
-Winding resistance measurement
-Saturated and non-saturated inductance test
-Transient CT parameters test
-CT/PT polarity test
-CT nameplate guess
Technical Data
○Test Standard: IEC61869-2(IEC60044-1,60044-6), IEC61869-3(IEC60044-2), IEEE/ANSI C57.13
○Maximum Knee Voltage Measurement: 40kV
○Output Range:
voltage: 0~180V(RMS)
current: 0~12A(RMS), 36A(peak value)
○Voltage Measurement Accuracy: ±0.05%
○CT Ratio Measurement:
range:1~30000
accuracy: ±0.05%
○PT Ratio Measurement:
range:1~10000
accuracy: ±0.05%
○Phase Measurement:
accuracy: ±2min
resolution: 0.01min
○Secondary Winding Resistance Measurement:
range: 0~300Ω
accuracy: 0.1%±1mΩ
○Burden Measurement:
range: 0~300VA
accuracy: 0.1%±0.1VA
○Memory Capacity: >3000 groups test results
○Power Supply
Nominal Input Voltage | Customized (AC 220V/230V/120V/127V±10%, 1-Phase) |
Nominal Frequency | 50/60 Hz |
Rated Current | 10A At 230V / 12A At 115V |
Connection | Standard AC Socket (IEC 60320) |
○Environmental Conditions
Operation Temperature | 0 ... +50 °C (+32 ... +122 °F) |
Storage Temperature | -25 ... +70 °C (-13 ... +158 °F) |
Humidity Range | Relative Humidity 5 ... 95 %, Non-Condensing |
Vibration | IEC 60068-2-6(20m/S2 At 10 ... 150 Hz) |
○Miscellaneous
Weight | 9kg / 19.84 Lbs |
Dimensions (W X H X D, Without Handle) | 340×300×150mm(13.39x11.81x5.91 In) |
Connection Port | 2 USB2.0 Ports, 1 Communication Port |
○Safety Standards, Electromagnetic Compatibility
EMC | The Product Adheres To The Electromagnetic Compatibility (EMC) Directive 2004/108/EC(CE Conform) |
IEC 61326-1; IEC 61000-6-4; IEC 61000-3-2/3 |
Safety | The Product Adheres To The Low Voltage Directive 2006/95/EC(CE Conform). |
IEC 61010-1 |
Ratio error and phase angle error of CT tested by voltage measurement method
Figure1 CT's equivalence principle diagram
CT's equivalence principle is shown as figure1. As we can know from the figure, the main reason of causing ratio error and phase angle error is the error of excitation loss's current Iex and turns ratio Np/Ns. So for 5%, 20%,100%,120% rated current output, if Iex amplitude and phase position and true turns ratio Np/Ns are known, then the ratio error and angle error of CT at this time can be calculated. The tester calculates the ratio error and phase angle error of CT by the measured turns ratio Np/Ns and excitation loss Iex.
Turns Ratio Np/Ns can be got by inputting voltage on the secondary side under no-load condition and test the primary induced voltage. Iex can be got by test the secondary side's excitation characteristics. Because Iex is determined by the induced electromotive force of secondary circuit, Iex amplitude and phase angle can be got from excitation characteristics. When the secondary current and the secondary load are known, Vex value is also can be got by calculation and get Iex value by checking out the excitation characteristics data table.
CT and PT Tester CTP-200P was showed at THE 9TH INTERNATIONAL EXHIBITION ON ELECTRICAL TECHNOLOGY & EQUIPMENT in SECC, Ho Chi Minh City.
CT and PT Tester CTP-200P is portable and reliable instrument for testing Current Transformers and Potential Transformers indoor or outdoor.
Certifications
CT and PT Tester CTP-200P is calibrated in in the third party laboratory accredited under ISO/IEC 17025. The calibration report is shown as below.
Company Profile
HAOMAI ELECTRIC POWER AUTOMATION is established in 1999 and located in Wuhan of China, which is specialized in developing and manufacturing electrical power test and measurement instruments. HAOMAI products are widely used in power grid, petrochemical, metallurgy, railway, coal mine, research institutes and all kinds of large-scale factories or enterprises.mainly focuses on the sales and services of Protection Relay Test System, CT/PT Analyzer, Battery Load Tester, Transformer Testing Equipment, Circuit Breaker Analyzer, Partial Discharge Detector etc. electrical power test and measurement instruments.
HAOMAI follows total quality criteria, and always maintains standardized process and procedures for continuous growth. HAOMAI has been certified by ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007.
HAOMAI builds own RELAYSTAR laboratory and performance test laboratory, and possesses professional production equipment and testing instruments in factory, such as Agilent 34401A 6 1/2 High-precision Meter, FLUKE Multi-meter, EMH Standard Meter, CLOU Standard Power Source, Oscilloscope, Phase Meter, Insulation Test System, High Voltage Dividers, AC High Voltage Generator, Time Calibration Tester, Standard Micro-resistance etc.
HAOMAI is China well-known mark recognized and approved by State Administration for Industry & Commerce of People's Republic of China, and enjoys high reputation in domestic and foreign markets.
HAOMAI now is the key supplier for SGCC(State Grid Corporation of China) and CSG(China Southern Power Grid). Till 2018 HAOMAI products have been sold to 34 different countries.
HAOMAI always sticks to the faith of "cooperation and sharing", takes the "technology and market" as the direction, "creation and innovation" as the soul, listens to clients carefully, and improves the technology, upgrades the products, optimizes the service and tries all to be the global leader in electrical power test and measurement instruments field.
Our Advantages
Address:
Haomai Building No. 1, Wuhan University Science Park Road, East-Lake Hi-Tech Development District, Wuhan, Hubei, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics, Instruments & Meters, Manufacturing & Processing Machinery, Service
Management System Certification:
ISO 9001, ISO 14000
Company Introduction:
Wuhan HAOMAI Electric Power Automation Co., Ltd(HAOMAI for short)
Brand: RELAYTESTAR
Established in 1999;
Located in Wuhan China
Chinese sales amount(year 2017): $30, 000, 000+USD
Oversea sales amount(year 2017): $9, 000, 000+USD
HAOMA owned building: 35000 square meter
Employees: Total 150+ people,
Doctor degree: 1;
Master degree: 12+;
Bachelor degree: 50+;
Sales channels:
20 sales agents in China;
2 sales and technical agents in Asia
1 international sales branch company in Shenzhen
Technical support:
10+ well trained technical engineer 7*24 hours stand by.
Oversea technical support available
Main products:
1-6 phase relay protection testing system with high accuracy amplifier:
RELAYTESTAR-1600; RELAYTESTAR-1200; RELAYTESTAR-806; RELAYTESTAR-802; RELAYTESTAR-702; RELAYTESTAR-703; RELAYTESTAR-2000; RELAYTESTAR-406 and etc:
CT PT VT analyzer for protection/measuring CT/VT
CTP100P; CTP120P; CTP200P etc.
DC system testing equipment for substation
FDT110/220; FD110/220
Manufacture info:
Working capabilities: 2000+ sets/year
Certification: ISO9001; ISO14000;
Area: 2000 Square meter