  • Patented Rotary Mouse: Automatically completes tests in seconds using a patented multifunctional rotary mouse.
  • High Precision: Achieves 0.05% measurement accuracy for voltage, CT ratio, and PT ratio.
  • Portable Design: Weighs only 9kg (19.84 lbs) for easy transport to on-site testing locations.
  • High Voltage Support: Capable of testing knee-point voltage up to 40kV for CTs and PTs.
  • Comprehensive Testing: Tests excitation characteristics, error curves, polarity, and winding resistance.
  • Dual Operation Modes: Supports both local testing and PC remote control via Windows 7/10.
  • Built-in Printing: Features a built-in thermal printer to directly output test results.
  • Customizable Voltage: Nominal input voltage is customized to AC 220V/230V/120V/127V.

Product Images of Current and Voltage Transformer Calibrate System CT Analyzer

Current and Voltage Transformer Calibrate System CT Analyzer
Current and Voltage Transformer Calibrate System CT Analyzer pictures & photos
Current and Voltage Transformer Calibrate System CT Analyzer
Current and Voltage Transformer Calibrate System CT Analyzer pictures & photos
Current and Voltage Transformer Calibrate System CT Analyzer
Current and Voltage Transformer Calibrate System CT Analyzer pictures & photos
Current and Voltage Transformer Calibrate System CT Analyzer
Current and Voltage Transformer Calibrate System CT Analyzer pictures & photos
Current and Voltage Transformer Calibrate System CT Analyzer
Current and Voltage Transformer Calibrate System CT Analyzer pictures & photos
Current and Voltage Transformer Calibrate System CT Analyzer
Current and Voltage Transformer Calibrate System CT Analyzer pictures & photos
Current and Voltage Transformer Calibrate System CT Analyzer
  • Current and Voltage Transformer Calibrate System CT Analyzer
  • Current and Voltage Transformer Calibrate System CT Analyzer
    Current and Voltage Transformer Calibrate System CT Analyzer
  • Current and Voltage Transformer Calibrate System CT Analyzer
    Current and Voltage Transformer Calibrate System CT Analyzer
  • Current and Voltage Transformer Calibrate System CT Analyzer
    Current and Voltage Transformer Calibrate System CT Analyzer
  • Current and Voltage Transformer Calibrate System CT Analyzer
    Current and Voltage Transformer Calibrate System CT Analyzer
  • Current and Voltage Transformer Calibrate System CT Analyzer
    Current and Voltage Transformer Calibrate System CT Analyzer
  • Current and Voltage Transformer Calibrate System CT Analyzer
    Current and Voltage Transformer Calibrate System CT Analyzer

Find Similar Products

Product Description

Product Description

Descriptions
CT and PT Tester is the revolutionary testing system for various CTs and PTs according to standards IEC61869-2 (IEC60044-1,60044-6), IEC61869-3(IEC60044-2) and IEEE/ANSI C57.13. The Analyzer can automatically complete the test within seconds by one click of the patented multifunctional rotary mouse. It allows to test the knee-point voltage up to 40kV CTs and PTs on-site in power grids or in manufacturers' production facilities or test labs. 

CT and PT Tester CTP-200 is only 9kg(9.84 lbs), which is easy to carry on testing site.

 

Main Features
1) Able to test Protection CTs, Measuring CTs, TP class CTs and inductive PTs
2) Test excitation characteristic and error curve based on low-frequency measurement principle
3) Measure ratio, polarity, ratio error and phase displacement error based on voltage method
4) Automatic demagnetization of the CT after test.
5) Adopt patented multifunctional rotary mouse to replace the keypad
6) Adopt 5.7 inches LCD screen for display
7) Adopt DSP, ARM and embedded LINUX operation system
8) Both local test and PC remote test available
9) Higher measurement accuracy: 0.05 %
10) Print test results directly by built-in thermal printer
11) Small and light weight (9kg / 19.84 lbs) for easy transport

 

Application
-CT/PT excitation and saturation test
-Accuracy measurement of ratio and phase angle
-Secondary loop burden measurement
-Winding resistance measurement
-Saturated and non-saturated inductance test
-Transient CT parameters test
-CT/PT polarity test
-CT nameplate guess

 

Technical Data
○Test Standard: IEC61869-2(IEC60044-1,60044-6), IEC61869-3(IEC60044-2), IEEE/ANSI C57.13
○Maximum Knee Voltage Measurement: 40kV 


○Output Range:
voltage: 0~180V(RMS)
current: 0~12A(RMS), 36A(peak value) 


○Voltage Measurement Accuracy: ±0.05%
○CT Ratio Measurement:
range:1~30000
accuracy: ±0.05% 


○PT Ratio Measurement:
range:1~10000
accuracy: ±0.05% 


○Phase Measurement:
accuracy: ±2min
resolution: 0.01min 


○Secondary Winding Resistance Measurement:
range: 0~300Ω
accuracy: 0.1%±1mΩ 


○Burden Measurement:
range: 0~300VA
accuracy: 0.1%±0.1VA

 
○Memory Capacity: >3000 groups test results 


○Power Supply

Nominal Input Voltage

Customized (AC 220V/230V/120V/127V±10%, 1-Phase)

Nominal Frequency

50/60 Hz

Rated Current

10A At 230V / 12A At 115V

Connection

Standard AC Socket (IEC 60320)

 

○Environmental Conditions

Operation Temperature

0 ... +50 °C (+32 ... +122 °F)

Storage Temperature

-25 ... +70 °C (-13 ... +158 °F)

Humidity Range

Relative Humidity 5 ... 95 %, Non-Condensing

Vibration

IEC 60068-2-6(20m/S2 At 10 ... 150 Hz)

 

○Miscellaneous

Weight

9kg / 19.84 Lbs

Dimensions (W X H X D, Without Handle)

340×300×150mm(13.39x11.81x5.91 In)

Connection Port

2 USB2.0 Ports, 1 Communication Port

 

○Safety Standards, Electromagnetic Compatibility

EMC

The Product Adheres To The Electromagnetic Compatibility (EMC) Directive 2004/108/EC(CE Conform)

IEC 61326-1; IEC 61000-6-4; IEC 61000-3-2/3

Safety

The Product Adheres To The Low Voltage Directive 2006/95/EC(CE Conform).

IEC 61010-1

 

Ratio error and phase angle error of CT tested by voltage measurement method 
Current and Voltage Transformer Calibrate System CT Analyzer

Figure1 CT's equivalence principle diagram

 

CT's equivalence principle is shown as figure1. As we can know from the figure, the main reason of causing ratio error and phase angle error is the error of excitation loss's current Iex and turns ratio Np/Ns. So for 5%, 20%,100%,120% rated current output, if Iex amplitude and phase position and true turns ratio Np/Ns are known, then the ratio error and angle error of CT at this time can be calculated. The tester calculates the ratio error and phase angle error of CT by the measured turns ratio Np/Ns and excitation loss Iex.

 

Turns Ratio Np/Ns can be got by inputting voltage on the secondary side under no-load condition and test the primary induced voltage. Iex can be got by test the secondary side's excitation characteristics. Because Iex is determined by the induced electromotive force of secondary circuit, Iex amplitude and phase angle can be got from excitation characteristics. When the secondary current and the secondary load are known, Vex value is also can be got by calculation and get Iex value by checking out the excitation characteristics data table.
CT and PT Tester CTP-200P was showed at THE 9TH INTERNATIONAL EXHIBITION ON ELECTRICAL TECHNOLOGY & EQUIPMENT in SECC, Ho Chi Minh City. 
Current and Voltage Transformer Calibrate System CT AnalyzerCT and PT Tester CTP-200P is portable and reliable instrument for testing Current Transformers and Potential Transformers indoor or outdoor. 
Current and Voltage Transformer Calibrate System CT Analyzer

Certifications

CT and PT Tester CTP-200P is calibrated in in the third party laboratory accredited under ISO/IEC 17025. The calibration report is shown as below. 
Current and Voltage Transformer Calibrate System CT Analyzer

Company Profile

Current and Voltage Transformer Calibrate System CT AnalyzerCurrent and Voltage Transformer Calibrate System CT AnalyzerCurrent and Voltage Transformer Calibrate System CT AnalyzerCurrent and Voltage Transformer Calibrate System CT AnalyzerCurrent and Voltage Transformer Calibrate System CT Analyzer
Current and Voltage Transformer Calibrate System CT AnalyzerCurrent and Voltage Transformer Calibrate System CT AnalyzerHAOMAI ELECTRIC POWER AUTOMATION is established in 1999 and located in Wuhan of China, which is specialized in developing and manufacturing electrical power test and measurement instruments. HAOMAI products are widely used in power grid, petrochemical, metallurgy, railway, coal mine, research institutes and all kinds of large-scale factories or enterprises.mainly focuses on the sales and services of Protection Relay Test System, CT/PT Analyzer, Battery Load Tester, Transformer Testing Equipment, Circuit Breaker Analyzer, Partial Discharge Detector etc. electrical power test and measurement instruments.
 
HAOMAI follows total quality criteria, and always maintains standardized process and procedures for continuous growth. HAOMAI has been certified by ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007.
 
HAOMAI builds own RELAYSTAR laboratory and performance test laboratory, and possesses professional production equipment and testing instruments in factory, such as Agilent 34401A 6 1/2 High-precision Meter,Multi-meter, EMH Standard Meter, CLOU Standard Power Source, Oscilloscope, Phase Meter, Insulation Test System, High Voltage Dividers, AC High Voltage Generator, Time Calibration Tester, Standard Micro-resistance etc.
 
HAOMAI is China well-known mark recognized and approved by State Administration for Industry & Commerce of People's Republic of China, and enjoys high reputation in domestic and foreign markets.
 
HAOMAI now is the key supplier for SGCC(State Grid Corporation of China) and CSG(China Southern Power Grid). Till 2018 HAOMAI products have been sold to 34 different countries. 
 
HAOMAI always sticks to the faith of "cooperation and sharing", takes the "technology and market" as the direction, "creation and innovation" as the soul, listens to clients carefully, and improves the technology, upgrades the products, optimizes the service and tries all to be the global leader in electrical power test and measurement instruments field.

Our Advantages

Current and Voltage Transformer Calibrate System CT Analyzer

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR259752". Items marked "verified" are certified.

Watch Video
Watch Video
Haomai Electric Power Automation Co., Ltd.
Haomai Electric Power Automation Co., Ltd.
Haomai Electric Power Automation Co., Ltd.
Haomai Electric Power Automation Co., Ltd.
Haomai Electric Power Automation Co., Ltd.
Haomai Electric Power Automation Co., Ltd.
Haomai Electric Power Automation Co., Ltd.
Haomai Electric Power Automation Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Haomai Building No. 1, Wuhan University Science Park Road, East-Lake Hi-Tech Development District, Wuhan, Hubei, China
verified Plant Area
6712 square meters
verified Number of Employees
149
verified Registered Capital
110,000,000 RMB
verified Terms of Payment
T/T
verified International Commercial Terms(Incoterms)
CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port
verified Minimum Order Quantity
1 Set
verified Supply Chain Partners
3000

Our Production Capability & Technical Expertise

verified Main Products
CT PT Analyzer, Relay Protection Test System, Substation DC System Tester, Battery Test System
verified Production Lines
3
verified Production Machines
Assembling Lines, Debugging Lines, Aging Testing Lines
verified QA/QC inspectors
8 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
35 people
verified Traceability of Raw Materials
Yes
verified Test Reports for Raw Materials
Others
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
1999-07-27
verified Export Year
4 Years
verified Main Markets
Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
3
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Management System Certification
ISO14001, ISO45001:2018

FAQ

What is the warranty period for this CT/PT Analyzer?
The product comes with a 1-year warranty.
What is the maximum knee-point voltage this tester can handle?
The tester can measure knee-point voltage up to 40kV for CTs and PTs.
How accurate is the measurement of this device?
It offers high measurement accuracy of 0.05% for voltage, CT ratio, and PT ratio.
Is this device portable and suitable for on-site use?
Yes, it weighs only 9kg (19.84 lbs), making it lightweight and easy to carry for on-site testing in power grids or labs.
What standards does this CT/PT Tester comply with?
It complies with IEC61869-2, IEC61869-3, and IEEE/ANSI C57.13 standards.
Can I control the tester remotely from a PC?
Yes, it supports remote control via Windows 7 or Windows 10, in addition to local testing.
What is the minimum order quantity (MOQ)?
The minimum order quantity is 1 set.
What are the payment terms for this product?
The terms of payment are T/T (Telegraphic Transfer).
What is the average lead time for production?
The average lead time is within 15 workdays for both peak and off-season periods.
Does the manufacturer offer OEM or ODM services?
Yes, the manufacturer offers both OEM and ODM services, including customization from samples, designs, and flexible customization.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now